Multivoltage STAR DELTA timer relay 1 DIN
• It serves for delay ON of three-phase motor star/delta
• Time t1 (star)
- Time range setting by rotary switch
- Fine time setting by potentiometer
• Time t2 delay between star / delta
- Fine time setting by potentiometer
• Red LED multifunction flashes or shines depending on the operating status
• Supply terminals A1 – A2
• Power supply AC/DC 12-240 V (AC 50/60 Hz)
• Power input (max.) 2 VA/1,5 W
• Supply voltage tolerance -15% +10%
• Supply indication green LED
• Time scale t1: 0,1 s - 100 days, t2: 0,1 s - 1 s
• Setting switch and potentiometer
• Time tolerance 5% mechanical setting
• Accuracy repeat 0,2% on the set value
• Output type 2 changeover contacts
• Contacts material AgNi
• Current rating 16 A / AC1
• Inrush current 30 A / 3 s
• Breaking capacity 4.000 VA / AC1, 384 W/DC
• Switching voltage 250V AC/24V DC
• Power dissipation(contacts) max 1.2 W
• Output indication multifunction red LED
• Electrical life 50.000 operations
• Mechanical life 10.000.000 operations
• Reset time max. 150 ms
• Civil / tertiary / industrial use
• Type installation DIN rail
• Protection degree (IP) IP20 / IP40 rear panel
• Dielectrical strength 4.000 V ac
• Max cross-section of wires to terminals 1 x 2,5 or 2 x 1,5 mmq, 1 x 2,5 mmq with cable lug
• Operating temperature -20 ÷ 55°C
• Storing temperature -30 ÷ 70°C
• Degree of pollution 2
• Overvoltage category III
• Standard EN 61812-1
• Dimensions (L x W x H) mm 17,6 x 64 x 90
• Weight 78 g.