MIDI industrial relay, 4 contacts 12V a.c.
Power supply 12V a.c.
4 changeover contacts 10A / 250V
MIDI industrial relay, 4 contacts 12V a.c.
Power supply 12V a.c.
4 changeover contacts 10A / 250V
TECHNICAL SPECIFICATIONS
Main data
Type:
MIDI-2
Power supply voltage:
12 - 24 - 48 - 60V d.c. (mod DC)
12 - 24 - 48 - 110 - 230V a.c. (mod AC)
Rated load:
10A / 250Va.c. - 30V d.c. (MIDI-2)
5A / 250Va.c. - 30V d.c. (MIDI-4)
Load in AC1:
12A / 250Va.c. - 30V d.c. (MIDI-2)
6A / 250Va.c. - 30V d.c. (MIDI-4)
Max commutable power:
2500VA / 300W (MIDI-2)
1250VA / 300W (MIDI-4)
Max commutable voltage:
250V a.c. / 30V d.c.
Motor power:
1/3 HP a 240V a.c. (MIDI-2)
1/6 HP a 240V a.c. (MIDI-4)
Contact material:
AG - CdO
Type of Operation:
monostable
Description
Use:
tertiary / industrial
Type of outputs:
potential-free changeover
Available contacts:
2 changeover (2 x ) (MIDI-2)
4 changeover (3 x ) (MIDI- 4)
Dimensions (L x W x H) mm:
21,5 x 28 x 36
Weight:
37 g.
General data
Type of installation:
on socket
Protection degree (IP):
IP 20
Electrical life (operations):
100.000
Mechanical life (operations):
10.000.000
Insulation resistance (500 V d.c.):
1.000 MO
Dielectric strength (open contacts):
750 V a.c. (MIDI-2)
1.550V a.c. (MIDI-4)
Dielectric strength (contacts/coil):
3.750 V a.c.
Minimum load:
100 mA / 5 V d.c.
Dissipated power:
0.9 W (mod DC)
1.2 VA (mod AC)
Operating temperature limits from:
-55°C to +70°C
Intervention time (with rated voltage)
25 msec max
Release time (with rated voltage):
25 msec max
Room temperature:
-55 ÷ + 70 °C
Resistance to vibrations:
10 ÷ 55 Hz 1.5 mm
Resistance to collisions (functional):
100 m / sec2 /10 g
Resistance to collisions (destructive):
1.000 m / sec2 /100 g
Humidity:
35 % ÷ 95 %
Construction:
dust-proof cover
Insulation rated voltage:
250 V
Withstand voltage at rated imp.:
2,2 KV
Pollution rating:
2
Overvoltage category:
III